Electric Long-Tube Air Supply Blower (2-Person)

Electric Long-Tube Air Supply Blower (2-Person)

Motorized long-tube breathing-air blower serving two users simultaneously for extended confined-space work.

Dual-person electric long-line air supply blower, strictly manufactured in accordance with GB6220-2009 "Respiratory protection - Long-line breathing apparatus" and GB27901-2011 "Mobile fire smoke exhaust fan" national standards. It is core respiratory protection supporting air supply equipment for two-person collaborative operations and emergency rescue, and can be batch purchased to meet the needs of two-person operations in various high-risk scenarios. The core function of the product is to filter the clean outside air and stably deliver it to two operators through dual long hoses, achieving constant-flow positive-pressure air supply, isolating toxic and harmful gases, dust, and smoke, solving the pain point of respiratory protection in confined, oxygen-deficient environments during two-person collaborative operations, ensuring that both operators simultaneously receive sufficient clean air, not limited by working hours, and can work continuously 24/7. The blower is made of high-quality 304 stainless steel or wear-resistant engineering plastics, with excellent external anti-corrosion, rust-proof, and anti-oxidation properties, protecting the internal circuit and extending service life. It is equipped with a built-in vortex jet blower, with a compact structure, inlet and outlet valves, and a silencing device, featuring low energy consumption, high efficiency, sufficient air supply pressure, large exhaust volume, and low noise. It is paired with dual independent air supply interfaces, allowing individual flow adjustment to meet the different breathing needs of two operators. The equipment is equipped with an audible and visual alarm system that can promptly issue an alarm signal in case of power outage to remind operators to evacuate, while also supporting switching to self-priming mode for emergency breathing. The overall size is compact, with moderate weight, easy to carry and move, simple to operate, no complex training required, and starts air supply upon power connection. It has complete qualifications, comes with test reports and explosion-proof certification, combining stability, practicality, and safety. It is essential respiratory protection equipment for two-person collaborative operations in various high-risk places such as chemical plants, mines, confined space operations, and fire rescue.

Technical Specifications (Selection Reference)

Values are industry-standard ranges; final configuration subject to scheme design.

Specifications

ModelTwin-person electric model (standard / explosion-proof), compatible with single-person use, and some models can be expanded to 4-person use.
Main Material304 stainless steel or engineering plastic, anti-corrosion, wear-resistant, and oxidation-resistant.
Drive ModeElectric drive, power supply: 220V AC/50Hz (12V DC model optional).
Rated Power90-180W, speed 2800r/min.
Air Supply ParametersConstant-flow air supply, total supply 300-350 L/min, single-line supply ≥150 L/min, supply pressure ≥7 KPa, adjustable flow rate as needed
Long Hose ConfigurationDual-line polyurethane or imported ethylene corrugated hose, standard length 20 m per line, inner diameter 25 mm, customizable 10-50 m length
Alarm FunctionBuilt-in audible and visual alarm system, automatically alarms upon power failure, alarm sound level ≥85 dB
Protective PerformanceProtection rating IP65, dustproof and waterproof, suitable for harsh environments such as humidity and dust
Dimensions300×250×240 mm - 385×162×162 mm (varies slightly by power model)
Net Weight5-15kg, portable and easy to move
Operating Temperature-30℃~60℃, humidity ≤93%RH (non-condensing)
StandardGB6220-2009, GB27901-2011, with explosion-proof certification (Exia IIC T4 Ga), complete qualifications, each unit comes with a test report, supports batch supply, and provides customized long hose length and power configuration services

Certification: Test Report, Factory Certificate of Conformity · Customization (explosion-proof, anti-corrosion etc.) available

Product Details

Dual-person electric long-line air supply blower, strictly manufactured in accordance with GB6220-2009 "Respiratory protection - Long-line breathing apparatus" and GB27901-2011 "Mobile fire smoke exhaust fan" national standards. It is core respiratory protection supporting air supply equipment for two-person collaborative operations and emergency rescue, and can be batch purchased to meet the needs of two-person operations in various high-risk scenarios. The core function of the product is to filter the clean outside air and stably deliver it to two operators through dual long hoses, achieving constant-flow positive-pressure air supply, isolating toxic and harmful gases, dust, and smoke, solving the pain point of respiratory protection in confined, oxygen-deficient environments during two-person collaborative operations, ensuring that both operators simultaneously receive sufficient clean air, not limited by working hours, and can work continuously 24/7. The blower is made of high-quality 304 stainless steel or wear-resistant engineering plastics, with excellent external anti-corrosion, rust-proof, and anti-oxidation properties, protecting the internal circuit and extending service life. It is equipped with a built-in vortex jet blower, with a compact structure, inlet and outlet valves, and a silencing device, featuring low energy consumption, high efficiency, sufficient air supply pressure, large exhaust volume, and low noise. It is paired with dual independent air supply interfaces, allowing individual flow adjustment to meet the different breathing needs of two operators. The equipment is equipped with an audible and visual alarm system that can promptly issue an alarm signal in case of power outage to remind operators to evacuate, while also supporting switching to self-priming mode for emergency breathing. The overall size is compact, with moderate weight, easy to carry and move, simple to operate, no complex training required, and starts air supply upon power connection. It has complete qualifications, comes with test reports and explosion-proof certification, combining stability, practicality, and safety. It is essential respiratory protection equipment for two-person collaborative operations in various high-risk places such as chemical plants, mines, confined space operations, and fire rescue.

Instructions and operating specifications: For storage, choose a dry, ventilated, unobstructed location that is easy to access, away from fire sources, power sources, high temperatures, and flammable, explosive, toxic, or harmful gas areas. Avoid direct sunlight, severe impact, and liquid immersion. The storage environment temperature should be controlled at -10℃~40℃. Take moisture-proof and dust-proof measures. Coil the long hoses neatly and place them in a dedicated storage box. If not used for a long time, run the blower for 5 minutes every month to check the fan's operating status and alarm function to prevent component aging. Before use, perform a comprehensive inspection of the blower: check that the fan appearance is free of damage, wires are free of damage and aging, long hoses are free of damage, blockage, and leakage, and connection interfaces are not loose; check that the audible and visual alarm system is normal; after power-on, the standby green light is on, and after startup, the red light is on; cutting off power triggers the alarm; check that the filter is clean and free of debris blockage. Place the blower main unit in an environment with clean outside air, ensure the air inlet is unobstructed, and ground properly to avoid static accumulation. During installation and operation, connect the two long hoses to the fan interfaces by rotating and tightening them. If multiple users are needed, a multi-way connector can be installed. Connect the other end of the long hoses to the breathing mask interface and secure it. Thread the long hoses through the belt buckle and tighten to prevent tugging from affecting mask wearing. Check the airtightness of the whole unit by sealing the end of the long hose with your hand and inhaling; if you feel resistance, the seal is good. Start the blower and test whether the air supply is stable and breathing is smooth before entering the work area. During use, both operators must simultaneously check the air supply status. If abnormal air volume, air interruption, or alarm sounds occur, immediately stop operations, evacuate to a safe area, and troubleshoot. It is strictly forbidden to place the blower main unit in a toxic or harmful environment, or to pull the long hoses arbitrarily to avoid loose interfaces and air leakage. Adjust the flow control valve according to operational needs to ensure breathing comfort. After use, turn off the power, disconnect the long hoses and masks, clean the fan surface, air inlet, and long hoses of dirt and dust, coil the long hoses neatly, check the blower, long hoses, and interfaces for damage, and repair or replace them promptly. Clean the filter, dry it, and store it in place. Keep equipment usage records. For daily maintenance, regularly check the fan motor operating status. Perform a thorough inspection every 3 months, clean internal dust, and check the sealing performance of wires and interfaces. Regularly replace filters and aging parts, check the wear of long hoses, and replace damaged long hoses promptly. It is strictly forbidden to disassemble or modify fan components arbitrarily, or to replace power supplies or parts in explosive environments. Non-professionals must not debug or repair the equipment without authorization. Ensure the blower is always in good operating condition. Service hotline: 130-6003-1111

Applications

Widely used in petrochemical enterprises, mines, confined space operations (sewage tanks, storage tanks, cellars, underground pipe trenches), fire rescue, tunnels, sewage treatment plants, laboratories, painting workshops, municipal underground construction, and other places with risks of toxic and harmful gases, dust, smoke, or oxygen deficiency. Suitable for two-person collaborative operations, emergency rescue, equipment maintenance, confined space construction, and other scenarios, especially for situations requiring two operators to enter high-risk environments simultaneously. The blower main unit is placed in a clean air environment, delivering clean air through long hoses to the operators' masks. It can be used with breathing masks to meet the respiratory protection needs of two people simultaneously, complies with various industrial safety regulations and fire protection requirements, and effectively ensures the life safety of two-person collaborative operators.

After-sales Policy

Nationwide direct logistics delivery; acceptance documents are handed over with the goods. Warranty and after-sales terms are subject to the supply contract. Government and enterprise group purchases are supported. For details, call for consultation.