Tripod, winch, harness and gas detection in one kit — mandated equipment for confined-space work and rescue.
Values are industry-standard ranges; final configuration subject to scheme design.
| Set Configuration | Core components include a gas detector (capable of detecting O₂, CO, H₂S, and combustible gases), a positive-pressure self-contained breathing apparatus (air supply duration 15-30 minutes), a rescue tripod (load capacity ≥200kg), a rescue rope (diameter ≥10mm, length ≥20m), a first aid kit (including hemostatic, dressing, disinfection and other first aid supplies), communication walkie-talkies (effective range ≥1km), chemical protective clothing, protective gloves, safety helmets, etc. |
| Main Material | The rescue tripod is made of high-strength aluminum alloy, the rescue rope is made of wear-resistant nylon fiber, the gas detector housing is made of waterproof and corrosion-resistant material, and the respirator cylinder is made of carbon steel or aluminum alloy, which is corrosion-resistant, high-strength, and wear-resistant. |
| Gas Detector | Detection accuracy ≤±5%FS, alarm method is audible and visual alarm, protection rating IP67, capable of real-time monitoring of various toxic and harmful gases and oxygen concentration. |
| Rescue Tripod | Retracted height ≤1.2m, extended height ≥2.0m, 360° rotation, equipped with braking device, firmly fixed. |
| Positive Pressure Air Breathing Apparatus | Working pressure: 21MPa, air cylinder capacity ≥600L, anti-fogging mask with airtight seal, built-in positive pressure protection system |
| Rescue Rope | Tensile strength ≥20kN, wear-resistant, not easy to break, equipped with safety lock |
| Protection Rating | Core components protection rating IP65 or above, dustproof, moisture-proof, waterproof and impact-resistant, adaptable to complex environments |
| Operating Temperature | -10℃~50℃, adaptable to different climates and confined spaces |
| Standard | GB 29510-2013, GB 30871-2022, complete certifications, each set includes test report, supports batch supply, customizable set configurations available |
Certification: Test Report, Factory Certificate of Conformity · Customization (explosion-proof, anti-corrosion etc.) available
Confined space rescue equipment, manufactured in strict compliance with GB 29510-2013 "Personal Protective Equipment - Safety Equipment for Confined Space Operations" and GB 30871-2022 "Safety Specifications for Special Operations in Hazardous Chemical Enterprises" as well as relevant national standards and confined space rescue regulations. It is the core equipment set for emergency rescue in confined spaces such as underground trenches, storage tanks, septic tanks, and tunnels, and can be batch purchased to suit various confined space rescue scenarios. The core function of the product is to provide protection for rescue personnel, while assisting in the search, rescue, and transfer of trapped persons, addressing rescue challenges such as oxygen deficiency, toxic and harmful gases, and narrow spaces in confined areas, ensuring the safety of rescue personnel and the successful rescue of trapped individuals. The full set of equipment meets the entire process requirements of reconnaissance, protection, rescue, and communication in confined spaces. The equipment set mainly includes gas detection instruments, positive pressure air respirators, rescue tripods, rescue ropes, first aid kits, communication equipment, and other core components. Each component is made of high-quality corrosion-resistant, high-strength materials, professionally treated for protection, compact in structure, portable and durable, suitable for complex environments such as narrow, humid, and dusty confined spaces. The design meets the actual needs of rescue operations, is easy to operate without complex training, and offers excellent protective performance, effectively resisting threats from toxic and harmful gases and oxygen-deficient environments. The rescue equipment has stable load-bearing capacity and high tensile strength, and the communication equipment enables real-time linkage between the rescue site and the outside world. With full certifications and relevant inspection reports, it balances practicality and safety, making it essential emergency rescue equipment for chemical enterprises, municipal, construction, mining, and other workplaces involving confined space operations.
Usage Instructions and Operating Specifications: When storing equipment, select a dry, ventilated, unobstructed, and easily accessible location away from fire sources, power sources, flammable, explosive, and toxic areas. Store items in an organized manner, taking measures to prevent moisture, dust, and damage. Post clear signage, regularly inspect the storage environment, and avoid equipment becoming damp or aging. Before use, conduct a comprehensive inspection of all equipment to ensure the gas detector has sufficient battery and accurate detection precision, the respirator cylinder pressure meets standards with no leaks, the rescue tripod is structurally stable with reliable brakes, the rescue rope has no damage and intact buckles, the communication equipment has clear signals, first aid supplies are complete and within their expiration dates, and all components are free of damage or looseness. During rescue operations, rescue personnel must first wear protective clothing, safety helmets, protective gloves, and other protective equipment, and don positive pressure air respirators. Use gas detectors to test the atmosphere in the confined space, and only proceed with rescue operations after confirming the environment is safe. Secure the rescue tripod at the entrance of the confined space, lower the rescue rope, and have rescue personnel enter the confined space via the rope while maintaining real-time communication with the outside through communication equipment, providing timely updates on conditions. During rescue, strictly prohibit unauthorized operations and prohibit rescue personnel from entering confined spaces alone. A dedicated attendant must be present, and the attendant must not leave the site without authorization. If abnormal gas concentrations are detected or rescue personnel experience discomfort, immediately initiate the emergency evacuation plan. After use, promptly clean, disinfect, and maintain all equipment. Calibrate gas detectors, refill respirator cylinders, clean and dry rescue ropes, replenish and replace first aid supplies, and organize and store all equipment properly. For routine maintenance, conduct comprehensive inspections of equipment regularly, calibrate gas detectors quarterly, and perform tensile strength tests on rescue tripods and rescue ropes annually. Promptly replace aged or damaged components. Strictly prohibit unauthorized disassembly or modification of equipment components, and prohibit using equipment for non-rescue purposes. Non-professionals must not debug or repair equipment without authorization, ensuring equipment is always in good emergency condition. Service hotline: 130-6003-1111
Widely used in petrochemical enterprises, municipal engineering, construction, mining, sewage treatment plants, warehousing and logistics, power facilities, and other places with confined spaces. Especially suitable for confined spaces such as underground trenches, underground warehouses, storage tanks, septic tanks, sewage wells, tunnels, and enclosed workshops that are narrow, sealed, and prone to oxygen deficiency and toxic or harmful gases. Suitable for emergency rescue scenarios such as sudden accidents and personnel entrapment during confined space operations. It can assist rescue personnel in completing rescue procedures including on-site reconnaissance, gas detection, personnel protection, transfer of trapped persons, and on-site first aid. It complies with confined space operation safety regulations and fire rescue requirements, effectively improving rescue efficiency in confined spaces, ensuring the safety of rescue personnel and trapped individuals, and filling the gap in supporting equipment for confined space rescue.
Nationwide direct logistics delivery; acceptance documents are handed over with the goods. Warranty and after-sales terms are subject to the supply contract. Government and enterprise group purchases are supported. For details, call for consultation.